Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 251

Advertising
background image

a-6

HD3070 with Automatic Gas Console

Instruction Manual

16

APPENDIX A

SIGNAL

PIN #

POL

DESCRIPTION

Gas Console Connector 3X4 CNC Interface (continued)

TEST

21

+

OPERATE
INPUT

TEST

22

+

PREFLOW
INPUT

REMOTE AIR

23

+

PLASMA

REMOTE

24

+

H35 & N

2

PLASMA

REMOTE O

2

25

+

PLASMA

COMMON

26

-

ERROR

27

OPEN

INPUT

COLL-
ECTOR

COMMON

28

-

THE CNC CAN ACTIVATE THIS INPUT TO FLOW CUTFLOW
GAS IN A TEST INPUT MODE. 12Vdc, 3mA

THE CNC CAN ACTIVATE THIS INPUT TO FLOW PREFLOW
GAS IN A TEST INPUT MODE. 12Vdc, 3mA

THE CNC CAN ACTIVATE THIS INPUT PLASMA GAS.
12Vdc, 3mA

THE CNC CAN ACTIVATE THIS INPUT PLASMA GAS.
12Vdc, 3mA

THE CNC CAN ACTIVATE THIS INPUT PLASMA GAS.
12Vdc, 3mA

SIGNAL COMMON.

SIGNAL COMMON.

THIS OUTPUT WILL BE ACTIVATED WHENEVER THERE IS
AN ERROR DISPLAYED ON THE LCD DISPLAY.