MAINTENANCE

OVERTEMP LED lit

Replace temperature
switch TS1 or TSW1.

Check temperature
switch wiring and
receptacle connections.

Allow to cool & operate
within rated duty cycle.

Allow to cool &
operate within
temperature range.

Replace fan M2
or M3.

Yes

No

Yes

Yes

Yes

Yes

No

No

Is

transformer T2 or

chopper

overheated

?

Was power supply

operated within rated

duty cycle

?

Was power supply

operated above ambient

temp

?

Is transformer T2

temperature switch TS1 or

chopper temperature switch

TSW1 defective ?

Is cooling fan M2

(chopper) or M3

(transformer)

defective ?

Allow for
recommended
clearances for
proper air flow.

Yes

No

Is cool air intake

or exhaust blocked

?

No