Maintenance – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 162

Advertising
background image

HD3070 with Automatic Gas Console

Instruction Manual

5-37

16

MAINTENANCE

Is high frequency

present at torch ?

Is T1 defective ?

Fig 6-11 (11)

Is

120 VAC applied

to high frequency
transformer T1 ?

Is PS/RHF control

cable defective ?

Fig 3-14

PS ERR=4

NO PILOT TIMEOUT ERROR

(Continued)

Is high frequency

present at torch ?

Check that high frequency
is present at torch. Caution,
use mirror to perform check.

Check power
supply DC output.

Replace
torch.

Replace
transformer
T1.

File, clean & regap
spark gaps.
Fig 6-11 (9)

Yes

Contact Hypertherm
technical service.

Contact Hypertherm
technical service.

Yes

Is high frequency

present at torch ?

Replace
torch
lead set.

Yes

Yes

Yes

No

No

Yes

Replace cable.

Replace relay PCB
1XPCB4.
Fig 6-2 (1)

Yes

Are spark gaps in

RHF unit firing ?

No

Replace
torch quick
disconnect.

No

No

No

No

Yes

Advertising