GS ERR=6

MOTOR VALVE 2 ERROR

Informs operator that motor valve 2 (MV2)

did not move when commanded.

To clear this error, power
down plasma system &
then reapply power.

Error corrected.

Replace MV2. Fig 6-13

No

No

Yes

Does MV2 error return

after reinitializing

plasma system ?

Does MV2 error return

after replacing MV2 &

reinitializing plasma

system ?

Yes

Does MV2 error return

after replacing control PCB

A1 & reinitializing plasma

system ?

Replace gas console
relay PCB A2.
Fig 6-12 (16)

Replace gas console
relay PCB A1.
Fig 6-12 (8)

Yes

Does MV2 error return

after replacing relay PCB A2

& reinitializing plasma

system ?

Contact Hypertherm
technical service.