background image

HD3070 with Automatic Gas Console

Instruction Manual

5-61

16

MAINTENANCE

REC2

REC3

REC4

REC1

1

Power Supply

Relay Board LED Status – Test Cut Flow

Figure 5-5

Power Supply Relay Board LED Status (2 of 4)

Auto Off
Relay LED
(D26)
P5.1

Output
Enable
LED (D20)

+12 VDC
LED (D6)

Surge Relay
CR4/
LED (D13)
P5.4

Plasma
On/Off
LED (D9)
P6.0

Shield
Operate/
LED (D14)
P6.3

Message
Number/
LED (D15)
P6.4

3

2

3

2

Air Plasma
LED (D16)
P6.5

H35 & N

2

Plasma/
LED (D17)
P6.6

O

2

Plasma

LED (D18)
P6.7

1 – Illuminates when using 50 to 100 amps.

2 – Remains off until any error.

3 – Illuminates when gas is selected.

3

LED On

LED Off