Status LED Troubleshooting

Be certain that the power supply has been through the Initial Checks as outlined earlier in this section before
troubleshooting STATUS LEDs. When any one of the STATUS LEDs does not illuminate (except OVERTEMP
illuminates) there is a fault condition that must be corrected in order for the HD3070 power supply to become
operational. The LEDs are connected in series, so the upper-most LED that does not illuminate (except
OVERTEMP does not extinguish) represents the first condition that must be corrected. Refer to the problems and
probable causes and solutions and the troubleshooting flow diagrams below. See wiring diagrams and gas and
coolant system schematics at back of manual for reference.

LED illuminated

LED extinguished

Problem

Possible Causes / Solutions

1. RHF INTERLOCK LED

extinguished:

1.1. Door to Remote HF console not completely shut.

This LED will illuminate when switch S1 located in the Remote
HF console is closed. If door is closed, check pins, connectors
and associated wiring for good continuity from receptacle 2X1
to 1X5.

Repair and/or replace defective component(s), if necessary.

2. OVERTEMP LED

illuminated:

2.1. Main Transformer T2 or chopper is overheating.

This LED will extinguish when the main transformer (T2) is
operating in a normal temperature range( (under 165° Ctr) and
the chopper is operating in the normal temperature range
(under 82° C). Temperature switch TS1 (transformer) or TSW1
(chopper) will open and will cause the LED to illuminate when
overheating occurs.

• Check temperature switches TS1 and TSW1 (normally

closed).

• Check pins, connectors and associated wiring to

temperature switches.

• Leave the fans running, and try restarting the unit after one

hour. If the LED still illuminates the transformer or chopper
may have to be replaced.

RHF INTERLOCK

OVER TEMP

EXT INTERLOCK

GAS SYSTEM

GAS PRESSURE

COOLANT TEMP

COOLANT FLOW

STATUS

3070STAT.01

RHF INTERLOCK

OVER TEMP

EXT INTERLOCK

GAS SYSTEM

GAS PRESSURE

COOLANT TEMP

COOLANT FLOW

STATUS

3070STAT.02