Gas system error message flow diagrams -47, Maintenance – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 172

Advertising
background image

HD3070 with Automatic Gas Console

Instruction Manual

5-47

16

MAINTENANCE

PS ERR=13

PHASE LOSS ERROR

Informs operator that the phase loss

protection circuit has shutdown the

system due to voltage phase loss or

input voltage dropping below 80% of

nominal.

Replace contactor.
Fig 6-26 (7)

Error corrected.

No

Yes

No

To clear this error, power
down plasma system &
then reapply power.

Return system to
service when input line
voltage problem is
corrected.

Yes

Did input

line voltage experience

a phase loss or

drop below 80%

nominal ?

Does

PHASE LOSS ERROR 13

return after reinitializing

plasma system ?