a-2

HD3070 with Automatic Gas Console

Instruction Manual

16

APPENDIX A

Power Supply CNC Interface Signals

Power Supply Connector 1X1 Standard Interface

SIGNAL

PIN #

POL

DESCRIPTION

EXTERNAL

16

+

CNC MUST PROVIDE A CLOSED CKT TO ALLOW POWER

INTERLOCK

17

-

SUPPLY OPERATION. 12VDC, 80MA SINK REQUIRED.

INPUT

18

SHLD

1/50 ARC

33

+

SIGNAL PROPORTIONAL TO ARC VOLTS 4VDC OUTPUT WITH

VOLTAGE

28

-

200Vdc ARC. OUTPUT IS ISOLATED AND FLOATING.

OUTPUT

27

SHLD

INTERLOCKS

35

DRY

DRY CONTACT CLOSURE THAT IS CLOSED WHEN ALL

OK

30

DRY

POWER SUPPLY INTERLOCKS ARE SATISFIED.

OUTPUT

24

SHLD

TRANSFER

32

DRY

DRY CONTACT CLOSURE THAT IS CLOSED WHEN

OUTPUT

37

DRY

TRANSFER OCCURS. USED TO START PIERCE COMPLETE

26

SHLD

AND MACHINE MOTION TIMING.

POWER ON

29

+

CNC MUST PROVIDE A CLOSED CKT TO POWER UP

INPUT

34

-

THE POWER SUPPLY. CNC SHOULD MAINTAIN UNTIL

23

SHLD

INTERLOCKS OK OUTPUT BECOMES ACTIVE AND THEN OK
OUTPUT BECOMES ACTIVE AND REMOVE. IF INTERLOCKS
OK OUTPUT IS NOT RECEIVED IN A REASONABLE TIME (20
SEC) THEN CHECK INDIVIDUAL INTERLOCKS. 12V dc, 80mA
SINK REQUIRED.

PLASMA ON

15

DRY

CNC MUST INITIATE DRY CONTACT CLOSURE TO START

INPUT

9

DRY

AND OPERATE PLASMA.

14

SHLD

POWER OFF

8

+

CNC SHOULD PROVIDE A MOMENTARY CLOSED CIRCUIT

INPUT

4

-

TO POWER DOWN THE POWER SUPPLY. INPUT IS 12V dc

13

SHLD

AND REQUIRES SINKING 80mA.