Status LED Troubleshooting Flow Diagrams

RHF INTERLOCK LED not lit

Check 1X5/2X1 receptacle
pins & wiring. Repair or replace
as required.

Close and
secure door.

Yes

No

Is RHF

door open?

Replace switch
S1.

Yes

Is RHF switch S1

defective ?

Fig 6-11 (3)

No

No

Replace or
connect cable.
Fig 3-14

Yes

Is

PS/RHF control

cable 1X5/2X1

defective or not

connected ?