PS ERR=4

NO PILOT TIMEOUT ERROR

Informs operator that high frequency

was unable to ignite pilot arc within

1 second.

Set correct preflow
gas flowrates.

Repair leaks or
remove twists in
gas lead set.

Yes

Yes

Yes

No

Yes

Are preflow gas

flowrates

set to correct values

?

Are torch back

pressures

within recommended

ranges ?

Are there leaks or

twists in gas lead set ?

Fig 3-25

Is current setting

correct ?

Are consumables of

correct type properly

installed & in good

condition ?

Yes

No

Set correct
value for current.

No

Install new
consumables of
correct type.

No

No