INSTALLATION

Connect Power Cable

After the power supply and line voltage disconnect box have been placed, connect the power cable to the power
supply first and then connect it to the line disconnect switch.

Power Supply

To connect the power cable to a 220/380/415V power supply (078024), refer to Appendix F.
For other power supply voltages use the procedure below.

1. Insert the power cable through the strain relief at the lower right rear of the power supply. Connect the power

cable leads to TB1 on the rear center panel of the right side (see Figure 3-4).

2. Connect the power leads to the L1 (U), L2 (V), and L3 (W) terminals of TB1. Make sure that all electrical

connections are tight to avoid excessive heating.

3. Connect the ground lead to the ground stud.

Line Voltage Disconnect Box

Connecting the power cable to the disconnect box must conform to national and local electrical codes. This work
should be performed only by qualified, licensed personnel.

Figure 3-4

Power Supply Power Cable Connections

Power Cable

Ground Stud
(PE)

Power Supply

TB1

L1
(U)

L2
(V)

L3
(W)

Ground

L1 (U)

L2 (V)

L3 (W)

Connect to Line Voltage
Disconnect Box