Maintenance – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 163

Advertising
background image

5-38

HD3070 with Automatic Gas Console

Instruction Manual

16

MAINTENANCE

PS ERR=5

PIERCE DELAY ERROR

Informs operator that PIERCE

COMPLETE signal was not received

from CNC controller within 4 seconds.

Replace cable.

Replace cable.

Correct CNC
programming for
PIERCE COMPLETE.

Replace relay PCB
1XPCB4.

Replace control PCB
1XPCB3. Fig 6-2 (4)

No

Yes

No

Yes

Was TRANSFER

signal received by

CNC controller ?

Is PS/machine
interface cable

defective ?

Fig 3-21

Is relay PCB 1XPCB4

defective ?

Fig 6-2 (1)

No

Did CNC send

PIERCE COMPLETE

signal within

4 seconds ?

Is PS/machine
interface cable

defective ?

Fig 3-21

No

Yes

No

Yes

Yes