Gas console error messages -30, Power supply system -30 – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 155

Advertising
background image

5-30

HD3070 with Automatic Gas Console

Instruction Manual

16

MAINTENANCE

Gas Console Error Messages

The gas console displays error messages for both the plasma system and gas system (Figure 5-3.1). The plasma
system and gas system messages are listed below. Following these error messages, troubleshooting flow
diagrams are provided to help resolve the problems causing the error messages.

Figure 5-3.1

Automatic Gas Console LCD Display

Indicates PS-ERR (power supply system error).
Refer to Power Supply System Error List.

Indicates GS-ERR (gas system error).
Refer to Gas System Error List.

00%

00%

00%

00%

00%

00%

INLET GAS

REMOTE or LOCAL

INLET GAS

PS-ERR

GS-ERR

XXX PSI/BAR

XXX PSI/BAR

XXX PSI/BAR

TEST, CALIBRATE or PURGE MODE

Power Supply System (PS-ERR)

Error Message

Error Code

Description

NO ERROR

0

LOW COOLANT LEVEL**

1

Indicates that the coolant reservoir needs to have coolant
added.

INTERLOCK ERR**

2

This error is issued during operation when one of the
pressure or temperature switches connected to the power
distribution PCB is opened.

HOLD TIMEOUT ERR**

3

This error signal is issued if the HOLD INPUT signal was not
released within 10 seconds after the end of preflow.

NO PILOT TIMEOUT ERR**

4

This error signal is issued when the high frequency was
unable to ignite the pilot arc within 1 second.