MAINTENANCE

PS ERR=6

TRANSFER TIMEOUT ERROR
Informs operator that transfer of

current to workpiece was not sensed

within 2 seconds.

Set correct torch
standoff. Refer to Cut
Charts in Section.

Is torch standoff

correct ?

Is there good

electrical contact

between workpiece &

work table ?

No

Check work cable
connection between power
supply & work table.

No

Set correct preflow
gas flowrates.

Install new
consumables of
correct type.

No

Check for leaks or
twists in gas lead set.

No

No

Yes

Yes

Are preflow gas

flowrates

set to correct

values ?

Are torch back

pressures

within recommended

ranges ?

Yes

Are consumables of

correct type properly

installed & in good

condition ?

Yes

Continued

on next

page

Yes