Maintenance – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 182

Advertising
background image

HD3070 with Automatic Gas Console

Instruction Manual

5-57

16

MAINTENANCE

GS ERR=10

MOTOR VALVE 6 ERROR

Informs operator that motor valve 6 (MV6)

did not move when commanded.

To clear this error, power
down plasma system &
then reapply power.

Error corrected.

Replace MV6. Fig 6-13

No

No

Yes

Does MV6 error return

after reinitializing

plasma system ?

Does MV6 error return

after replacing MV6 &

reinitializing plasma

system ?

Yes

Does MV6 error return

after replacing control PCB

A1 & reinitializing plasma

system ?

Replace gas console
relay PCB A2.
Fig 6-12 (16)

Replace gas console
relay PCB A1.
Fig 6-12 (8)

Yes

Does MV6 error return

after replacing relay PCB A2

& reinitializing plasma

system ?

Contact Hypertherm
technical service.

Yes

No

No

Advertising