Maintenance – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 180

Advertising
background image

HD3070 with Automatic Gas Console

Instruction Manual

5-55

16

MAINTENANCE

GS ERR=8

MOTOR VALVE 4 ERROR

Informs operator that motor valve 4 (MV4)

did not move when commanded.

To clear this error, power
down plasma system &
then reapply power.

Error corrected.

Replace MV4. Fig 6-13

No

No

Yes

Does MV4 error return

after reinitializing

plasma system ?

Does MV4 error return

after replacing MV4 &

reinitializing plasma

system ?

Yes

Does MV4 error return

after replacing control PCB

A1 & reinitializing plasma

system ?

Replace gas console
relay PCB A2.
Fig 6-12 (16)

Replace gas console
relay PCB A1.
Fig 6-12 (8)

Yes

Does MV4 error return

after replacing relay PCB A2

& reinitializing plasma

system ?

Contact Hypertherm
technical service.

Yes

No

No

Advertising