100 amp, Operation, Pac186 mild steel o – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 123: Plasma / o, Shield 100 amp cutting

Advertising
background image

4-34

HD3070 with Automatic Gas Console

Instruction Manual

16

OPERATION

Material

Thickness

(in)

(mm)

Arc

Voltage

(volts)

Torch

Standoff**

(in)

(mm)

Travel

Speed

(ipm)

(m/min)

Pierce

Delay

(dial)

(sec)

Initial

Piercing

Height

(in)

(mm)

1/8

3.2

10

100

35

90

60

137

0.125

3.2

275

7.0

0.180

4.6

0

0.00

1/4

6.4

10

100

35

90

60

141

0.125

3.2

135

3.43

0.300

7.6

0.4

0.22

3/8

9.5

10

100

35

90

60

145

0.125

3.2

95

2.41

0.300

7.6

0.7

0.27

1/2

12.7

10

100

35

90

60

147

0.125

3.2

64

1.62

0.300

7.7

1.0

0.37

Shield
120273

Nozzle
120272

Electrode
120410

Retaining Cap
120266

Swirl Ring
020637

PAC186 Torch
120349

Shield Cap
020634/020687

PAC186

Mild Steel

O

2

Plasma / O

2

& N

2

Shield

100 Amp Cutting

O

2

and N

2

gas inlet pressures must be between 105 - 135 psi (7.2 - 9.2 bar) for all material thickness.

#

Refer to LCD display Figure 4-3.

* Slightly increasing the test preflow O

2

and N

2

flowrates may increase piercing capability on the thicker materials listed

above. However, increasing the preflow flowrates too much may affect plasma starting reliability (misfiring).

** Torch standoff tolerances are ± 0.005 inch (± 0.125 mm). When using a THC, tolerances are ± 1 volt.

Counter clockwise (CCW) consumables are available for mirror image cutting. Refer to Section 6, Parts List.

If problems occur with the cutting process, and the flowrates are suspect, refer to Section 5, Maintenance, Gas System Back
Pressure Checks.

Test Cut

Flowrates (%)

Shield

O

2

N

2

(3)

#

(4)

#

Plasma

O

2

(5)

#

(6)

#

Test Preflow*

Flowrates (%)

Preflow

O

2

N

2

(1)

#

(2)

#

Advertising