Maintenance – Hypertherm HD3070 Plasma Arc Cutting System w/ Automatic Gas Console User Manual

Page 184

Advertising
background image

HD3070 with Automatic Gas Console

Instruction Manual

5-59

16

MAINTENANCE

Figure 5-4

Power Supply Relay Board (1XPCB4)

REC2

REC3

REC4

REC1

Auto Off Relay
LED (D26)
P5.1

+12 VDC
LED (D6)

Output
Enable
(Microprocessor Ready
LED (D20)

Machine
Motion
LED D24)
P5.0

Pilot Arc
Relay CR1/
LED (D11)
P5.6

H35 & N

2

Plasma Relay/
LED (D17)
P6.6

Message Number/
LED (D15)
P6.4

Surge Relay CR4/
LED (D13)
P5.4

Torch
Ignition/
LED (D28)
P5.2

Air Plasma
LED (D16)
P6.5

High Voltage
Transformer
T1/LED (D10)
P5.7

Shield Operate/
SV4,6,12/
LED (D14)
P6.3

Shield Preflow/
LED (D7)
P6.2

Main Contactor
CON1/LED (D12)
P5.5

Blowout
Counter
LED (D22)
P3.7

O

2

Plasma

Gas/LED (D18)
P6.7

Plasma On/Off
LED (D9)
P6.0

Not Used-Relay/
LED (D19)
P5.3

Not used-Relay/
LED (D8)
P6.1

Note:

The PX.X numbers called out above denote port locations on the microprocessor chip.

Advertising