Sample 1 - typical 3174 implementation, Typical 3174 implementation, Sample 1 - typical 3174 implementation -2 – Visara SCON-20L Installation User Manual

Page 74

Advertising
background image

6-2

707054-005

SCON-20L/22L/25L/28L/3074 Planning and Installation Guide

SAMPLE 1 - Typical 3174 Implementation

LPAR390

TEST1

Switch 01

C4

C5

1F

1E

This first example shows definitions where an ESCON director (switch 01) is being
used. The definitions shown may be used to define the SCON or even a 3174-22L. The
output ports C4 and C5 are being used to connect to two SCON-2XL(s).

CNTLUNIT CUNUMBR=1E00,PATH=1E,UNITADD=((00,5)),UNIT=3174,LINK=C5
CNTLUNIT CUNUMBR=1F00,PATH=1F,UNITADD=((00,5)),UNIT=3174,LINK=C4

RESOURCE PARTITION=((LPAR390,1),(TEST1,2))

CHPID PATH=(1F),TYPE=CNC,SWITCH=01,SHARED
CHPID PATH=(1E),TYPE=CNC,SWITCH=01,SHARED

IODEVICE CUNUMBR=1E00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)
IODEVICE CUNUMBR=1F00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)

Notes:

1. Each of the two 2XLs shown is dedicated to one of the two LPARs. This is not an

efficient use of the 2XL, but would be the necessary implementation of the 3174s.

2. The CNTLUNIT macros do not include the CUADD parameter, and the default value

of “0” would be assumed.