Sample 5 - emif and escon directors used, Emif and escon directors used, Sample 5 - emif and escon directors used -6 – Visara SCON-20L Installation User Manual

Page 78

Advertising
background image

6-6

707054-005

SCON-20L/22L/25L/28L/3074 Planning and Installation Guide

SAMPLE 5 - EMIF and ESCON Directors Used

LPAR390

TEST1

1F

EMIF

LPAR390B

TEST2

EMIF

Switch 01

C4

43

LPARS on two different CPUs are connected through an ESCON director to a single
SCON over a single ESCON interface. Users on the SCON can have sessions on any or
all of the 4 LPARs shown.

First CPU Definitions:

CNTLUNIT CUNUMBR=1E00,PATH=1F,UNITADD=((00,5)),UNIT=3174,CUADD=0,LINK=C4
CNTLUNIT CUNUMBR=1F00,PATH=1F,UNITADD=((00,5)),UNIT=3174,CUADD=1,LINK=C4

RESOURCE PARTITION=((LPAR390,1),(TEST1,2))

CHPID PATH=(1F),PARTITION=((LPAR390,TEST1)),TYPE=CNC,SHARED

IODEVICE CUNUMBR=1E00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)
IODEVICE CUNUMBR=1F00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)

Second CPU Definitions:

CNTLUNIT CUNUMBR=1195,PATH=43,UNITADD=((00,5)),UNIT=3174,CUADD=5,LINK=C4
CNTLUNIT CUNUMBR=2144,PATH=43,UNITADD=((00,5)),UNIT=3174,CUADD=6,LINK=C4

RESOURCE PARTITION=((LPAR390B,3),(TEST2,4))

CHPID PATH=(43),PARTITION=((LPAR390B,TEST2)),TYPE=CNC,SHARED

IODEVICE CUNUMBR=1195,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST2)
IODEVICE CUNUMBR=2144,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390B)

Notes:

1. Different CUADD values are required for each CNTLUNIT macro across both sets

of definitions since they will be sharing the same ESCON interface of the SCON,
unless Channel Path filtering is configured.

2. CUADD values do not have to be consecutive.

Advertising