Sample 3 - no emif, no director, No emif, no director, Sample 3 - no emif, no director -4 – Visara SCON-20L Installation User Manual

Page 76

Advertising
background image

6-4

707054-005

SCON-20L/22L/25L/28L/3074 Planning and Installation Guide

SAMPLE 3 - No EMIF, No Director

LPAR390

TEST1

1F

1E

This example shows one 25L/28L/3074 connected to two LPARs on one CPU. Because
EMIF is not being used, and because there is no ESCON director being used, each
LPAR must have a separate ESCON connection to the SCON. Only two LPARs can be
supported in this fashion. This is a very inefficient use of the SCON.

CNTLUNIT CUNUMBR=1E00,PATH=1E,UNITADD=((00,5)),UNIT=3174
CNTLUNIT CUNUMBR=1F00,PATH=1F,UNITADD=((00,5)),UNIT=3174

RESOURCE PARTITION=((LPAR390,1),(TEST1,2))

CHPID PATH=(1F),PARTITION=((LPAR390)),TYPE=CNC
CHPID PATH=(1E),PARTITION=((TEST1)),TYPE=CNC

IODEVICE CUNUMBR=1E00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(TEST1)
IODEVICE CUNUMBR=1F00,ADDRESS=(600,5),UNIT=3270-X,UNITADD=00,PARTITION=(LPAR390)

Note:

No CUADD parameter is shown, and the default value of “0” is being used on
each of the two ESCON interfaces. On the SCON, you would need to configure
“0” as the value for CU, for each of the two ESCON interfaces, in this example.