6196-2220

+DS – V.42 bis data compression

Description:

This command enables or disables V.42bis data compression if this feature is supported
on the product.

Syntax:

AT+DS=<dir>,<neg>,<P1>,<P2>

Command example

Possible responses

Note

AT+DS=? +DS: (0-3),(0,1),

Test

command

(512-4096),(6-250)

OK

AT+DS=3,0,4096,250

OK

Set new parameters

AT+DS?

+DS: 3,0,4096,20

Current values

OK

Defined values:

Four numeric sub-parameters are accepted:

<dir>

specifies the desired direction(s) of operation of the data compression function; from the
DTE point of view, (default is 3).

0:

Negotiated ... no compression

1:

Transmit only

2:

Receive only

3:

Both directions, accept any direction

<neg>

specifies whether or not the DCE should continue to operate if the desired result is not
obtained, (default is 0),

0:

Do not disconnect if V.42 bis is not negotiated by the remote DCE as
specified in <dir>

1:

Disconnect if V.42 bis is not negotiated by the remote DCE as specified in
<dir>

<P1>

512-4096:

specifies the maximum number of dictionary entries that should be
negotiated, (default is 4096).

<P2>

6-250:

specifies the maximum string length to be negotiated, (default is 250).