+CCED – Automatic RxLev indication

Description:

The CCED command has been extended to indicate the received signal strength indica-
tion (rssi) of the main cell.The command principle has not changed.

Syntax:

AT+CCED=<mode>[, <requested dump>]

Defined values:

<mode>

0:

One shot requested

1:

Automatic shots requested

2:

Stop automatic shots

<requested dump>

8:

Main cell RSSI indications (RxLev) from 0 to 31

The response will be a +CSQ response and not a +CCED response.
The 07.07 format for +CSQ is respected.The <ber> is not evaluated
by this command, so the <ber> value will always be 99.

+CSQ :<rssi>, 99

OK

This +CSQ response, when automatic shots are selected, is sent every time the <rssi>
measured by the product changes. Automatic shots are supported in idle mode and dur-
ing communication. Combination (addition of the values) of the requested dump (1,2,4,8)
are supported but the activation or deactivation of this flow (8) does not affect the other
flows. Both +CCED and +CSQ responses may then be generated. If the <requested
dump> parameter is absent, the last +CCED command parameter (or 15 by default) will
be used.