Westermo GD-01 User Manual

Page 17

Advertising
background image

17

6196-2220

+CALA – Alarm Management

Description:

This command is used to set alarms date/time in the ME.
The maximum number of alarms is 16. Seconds are not taken into account.

Syntax:

AT+CALA=<date and time string> (set alarm)

AT+CALA=””,<index> (delete alarm)

<date and time string> is a string with the following format:

“yy/MM/dd,hh:mm:ss”

Valid years are 98 (for 1998) to 97 (for 2097).
The seconds field is not mandatory.

<index> is a number from 0 to 15.

Command example

Possible responses

Note

AT+CALA=
”00/06/09,07:30”

OK

Set an alarm for June 9th,
2000 at 7:30 am,
alarm stored

AT+CALA=
”99/03/05,13:00:00”

+CME ERROR 3

Invalid alarm
(date/time expired)

AT+CALA?

+CALA:

list all alarms Note: three

“00/06/08,15:25:00”,0

alarms are set

+CALA:
“00/06/09,07:30:00”,1

(index 0, 1, 2)

+CALA:
“00/06/10,23:59:00”,2

+CALA:

An alarm occurs (index 0)

“00/06/08,15:25:00”,0

AT+CALA=””,2

OK

Delete alarm index 2
Note: Alarm index 2

deleted

AT+CALA? +CALA:

“00/06/09,07:30:00”,1

List all alarms,
only one alarm (index 1)