Westermo GD-01 User Manual
Page 85
85
6196-2220
+CAMM – Accumulated call meter maximum
Description:
The set command sets the Advice of Charge related to accumulated call meter maximum
value in SIM file EFACMmax . ACMmax contains the maximum number of home units the
subscriber is allowed to consume.When ACM (see +CACM) reaches ACMmax, calls are
prohibited. SIM PIN2 is required to set the value. If setting fails in an ME error, +CME
ERROR: <err> is returned.The Read command returns the current value of ACMmax.
The ACMmax value (entered or displayed) is in hexadecimal format with 6 digits.
Syntax:
AT+CAMM
Command example
Possible responses
Note
AT+CAMM=”000400”,1234 OK
Request
ACMmax
update,
PIN2 is “1234”,
result: ACMmax updated
to 1024
AT+CAMM=”000400”,0000 +CME
ERROR: 16
Request
ACMmax
update,
PIN2 is “1234”, result:
Incorrect password
AT+CAMM ?
+CAMM: “000400”
Request ACMmax value,
result: ACMmax = 1024
OK