Westermo GD-01 User Manual

Page 85

Advertising
background image

85

6196-2220

+CAMM – Accumulated call meter maximum

Description:

The set command sets the Advice of Charge related to accumulated call meter maximum
value in SIM file EFACMmax . ACMmax contains the maximum number of home units the
subscriber is allowed to consume.When ACM (see +CACM) reaches ACMmax, calls are
prohibited. SIM PIN2 is required to set the value. If setting fails in an ME error, +CME
ERROR: <err> is returned.The Read command returns the current value of ACMmax.
The ACMmax value (entered or displayed) is in hexadecimal format with 6 digits.

Syntax:

AT+CAMM

Command example

Possible responses

Note

AT+CAMM=”000400”,1234 OK

Request

ACMmax

update,

PIN2 is “1234”,
result: ACMmax updated
to 1024

AT+CAMM=”000400”,0000 +CME

ERROR: 16

Request

ACMmax

update,

PIN2 is “1234”, result:
Incorrect password

AT+CAMM ?

+CAMM: “000400”

Request ACMmax value,
result: ACMmax = 1024

OK

B A C K