6196-2220

GD-xx to ISDN (ID-90)

The necessary settings for data transmission between GD-xx and ID-90
(ISDN terminal adapter).

GSM in the dialling end

AT+CPIN=______

Insert PIN number if required

AT&F

To set the unit to factory default settings

AT+CBST=71,0,1

Bearer type selection. Choose data rate and protocol.
(9 600,V.110)

ID-90 in the receiving end

AT&F

To set the unit to factory default settings

ATB0

Sets the B channel protocol to V.110 asynchronous

ATN4

Sets line baudrate for B channel protocol V.110
to 9 600 bit/s

AT**V110LLC=1

Sets low layer compatibility to pass detailed information
about the V.110 protocol to the called party.

AT%B4

Sets local baudrate to 9 600 bit/s

If the settings described above is needed after power off its important to save the set-
tings with the following command.

AT&W

Store active configuration

Note:

When using an ISDN adapter it’s somethings needed to set up the MSN
(mutiple subscriber number) in the ISDN unit.
The command AT**MSN=nn is used when an S0 line is shared by several
adapters. (nn is the MSN of the ISDN adapter.
Example: If the number 999090 is called from the same area, no area code needs
to be stored with **MSN=999090. If the call is coming from an other country
then the country code + area code must be stored together with the number
i.e. **MSN=+4616999090. Please refer to the installation manual of the ID-90
for further information.