Data commands

+CBST – Bearer type selection

Description:

This command applies to both outgoing and incoming data calls, but in a different way.
For an outgoing call, the two parameters (e.g. <speed> and <ce>) apply, whereas for an
incoming call, only the <ce> parameter applies.

NOTE 1: For incoming calls, if <ce> is set to T only and the network offers NT only or

vice versa, then the call is released.

NOTE 2: The former values of 100 and 101 for <ce> are retained for compatibility pur-

poses but should no longer be used, values 2 and 3 should be used instead.

Syntax:

AT+CBST= <speed>, <name>, <ce>

Command example

Possible responses

Note

AT+CBST=?

+CBST:

Test command

(0-8,12,14,65,66,68,
70,71,75),(0),(0-3)

OK

AT+CBST=7,0,1

OK

Ask for a bearer, result:
Bearer supported

AT+CBST?

+CBST:7,0,1

Current values

OK

AT+CBST=81,0,0

+CME ERROR: 4

Ask for a bearer, result:
Bearer not supported

Defined values:

No data compression is provided and only asynchronous modem is supported
(<name> = 0).