5 jog operation using sigmawin – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 108

5.5 JOG Operation Using SigmaWin+
5-11
T
rial Operation (Checking Servomotor Operation)
5.5
JOG Operation Using SigmaWin+
This section describes the procedure for executing a JOG operation using Sig-
maWin+.
In the following example, procedures for trial operation are explained using the JOG
operation window of Test Run on the main menu of SigmaWin+.
Step
Operation
Display
1
• Connect a computer.
Use a connection cable to connect a SERVO-
PACK and a converter to a computer which
has SigmaWin+ installed.
–
2
• Start SigmaWin+ and open the main win-
dow.
(1) Turn ON the SERVOPACK and the con-
verter.
(2) Turn ON the computer.
(3) Double click the YE_Applications folder
on the desktop.
(4) Double click the SigmaWin+ icon to dis-
play the SigmaWin+ startup screen.
Startup Screen
Model:
JZSP-CVS06-02-E
CN7
PC
SERVOPACK
Connection cable
for personal
computer
YE_Applications
ψ
SigmaWin+
English Edition