3) wire size (ul standard), For three-phase, 200v – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 75

3.4 Main Circuit Wiring
3-27
Wiring and Connection
(3) Wire Size (UL Standard)
To comply with the UL standard, use the recommended wires.
The following table shows the wire sizes (AWG) at a rating of 75
°C.
For Three-phase, 200V
Combination of
SERVOPACK and
Converter
*
Terminal
Symbols
Screw Size
for
Terminals
Tightening
Torque
(Nxm)
Wire Size
AWG
SGDV-121H
SGDV-
COA2BAA
SERVOPACK
P, N
M8
15.0
Bus bar
attached to
the converter
U, V, W
M8
3.0
1/0
DU, DV, DW
M6
3.0
10
M8
9.0 to 11.0
1/0
Converter
P, N
M8
3.0
Bus bar
attached to
the converter
L1, L2, L3
M8
3.0
1/0
1, 2
M8
3.0 1/0
CN101
(L1C, L2C)
–
(Connector)
–
14
B1, B2
M8
3.0
6
M8
9.0 to 11.0
1/0
SGDV-161H
SGDV-
COA3GAA
SERVOPACK
P, N
M8
15.0
Bus bar
attached to
the converter
U, V, W
M8
3.0
3/0
DU, DV, DW
M6
3.0
10
M8
9.0 to 11.0
3/0
Converter
P, N
M10
12 to 20
Bus bar
attached to
the converter
L1, L2, L3
M10
12 to 20
3/0
1, 2
M10
12 to 20
3/0
CN101
(L1C, L2C)
–
(Connector)
–
14
B1, B2
M10
12 to 20
4
M8
9.0 to 11.0
3/0