2) wire sizes, For three-phase, 200v – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual

Page 70

Advertising
background image

3 Wiring and Connection

3.4.4 Main Circuit Wires

3-22

Note: These are reference values for 600-V-grade, heat-resistant, PVC-insulated wire.

(2) Wire Sizes

The following table shows the symbols for the power input terminals, screw sizes for
terminals, tightening torque, wire sizes, and crimp terminals used for the SERVO-
PACKs and converters.

„

For Three-phase, 200V

60

(2/0)

19/2.0

0.30

170

150

127

100

(4/0)

19/2.6

0.18

240

212

179

(cont’d)

Nominal

Cross

Section

Diameter

(mm

2

)

AWG

Size

Configuration

(Number of

Wires/mm)

Conductive

Resistance

(

Ω/km)

Allowable Current at

Surrounding Air Temperature

(A)

30

°C

40

°C

50

°C

Combination of

SERVOPACK and

Converter

*1

Terminal

Symbols

Screw Size

for

Terminals

Tightening

Torque

(Nxm)

HIV Wire Size

in mm

2

(AWG)

Crimp Terminal

Model

(Made by J.S.T.

Mfg Co., Ltd.)

*2

SGDV-121H

SGDV-

COA2BAA

SERVO-

PACK

P, N

M8

15.0

Bus bar

attached to the

converter

U, V, W

M8

3.0

60 (2/0)

R60-8

DU, DV,

DW

M6

3.0 5.5

(10)

R5.5-6

M8

9.0 to 1.0

60 (2/0)

R60-8

Converter

P, N

M8

3.0

Bus bar

attached to the

converter

L1, L2, L3

M8

3.0

38 (1)

R38-8

1, 2

M8

3.0 38

(1)

R38-8

CN101

(L1C, L2C)

(Connector)

1.25 (16)

B1, B2

M8

3.0

8 (8)

R8-8

M8

9.0 to 11.0

38 (1)

R38-8

Advertising