Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 76
Advertising
3 Wiring and Connection
3.4.4 Main Circuit Wires
3-28
∗ Use SERVOPACKs and converters in the specified combinations.
SGDV-201H
SGDV-
COA3GAA
SERVOPACK
P, N
M10
12 to 20
Bus bar
attached to
the converter
U, V, W
M10
30.0
250
DU, DV, DW
M6
3.0
10
M8
9.0 to 11.0
250
Converter
P, N
M10
12 to 20
Bus bar
attached to
the converter
L1, L2, L3
M10
12 to 20
4/0
1, 2
M10
12 to 20
4/0
CN101
(L1C, L2C)
–
(Connector)
–
14
B1, B2
M10
12 to 20
4
M8
9.0 to 11.0
4/0
(cont’d)
Combination of
SERVOPACK and
Converter
*
Terminal
Symbols
Screw Size
for
Terminals
Tightening
Torque
(Nxm)
Wire Size
AWG
Advertising