2 Installation
2.1.3 Installation Conditions for Applicable Standards
2-4
• Other Locations
Do not mount the SERVOPACK and the converter in locations subject to high tem-
peratures, high humidity, dripping water, cutting oil, dust, iron filings, or radiation.
<Note>
When storing the SERVOPACK and the converter with the power OFF, store it in an
environment with the following temperature and humidity:
• -20 to +85
°C, 90% RH or less. (with no condensation)
2.1.3 Installation Conditions for Applicable Standards
Applicable
Standards
UL508C
EN 50178, EN 55011 group1 classA, EN 61000-6-2, EN 61800-3,
EN 61800-5-1, EN 954-1, IEC 61508-1 to 4
Operating
Conditions
Overvoltage Category: III
Pollution degree: 2
Protection class: IP10
Installation
Conditions
UL Standard and Low Voltage Directive:
Satisfy the conditions outlined in AC SERVOPACK and Converter
Σ
-V
Series Safety Precautions For Use with Large-Capacity Models (manual
no.: TOBP C710829 07)
EMC Directive:
Certification is required after installation in the user’s machine under the
conditions outlined in 2.4 EMC Installation Conditions of this manual.