Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual

Page 71

Advertising
background image

3.4 Main Circuit Wiring

3-23

Wiring and Connection

∗1. Use SERVOPACKs and converters in the specified combinations.

∗2. Use the crimp terminals that are recommended by Yaskawa or an equivalent.

SGDV-161H

SGDV-

COA3GAA

SERVO-

PACK

P, N

M8

15.0

Bus bar

attached to the

converter

U, V, W

M8

3.0

100 (4/0)

CB100-S8

DU, DV,

DW

M6

3.0 5.5

(10)

R5.5-6

M8

9.0 to 11.0

100 (4/0)

100-8

Converter

P, N

M10

12 to 20

Bus bar

attached to the

converter

L1, L2, L3

M10

12 to 20

60 (2/0)

R60-10

1, 2

M10

12 to 20

60 (2/0)

R60-10

CN101

(L1C, L2C)

(Connector)

1.25 (16)

B1, B2

M10

12 to 20

14 (6)

R14-10

M8

9.0 to 11.0

60 (2/0)

R60-8

SGDV-201H

SGDV-

COA3GAA

SERVO-

PACK

P, N

M10

12 to 20

Bus bar

attached to the

converter

U, V, W

M10

30.0

100 (4/0)

R100-10

DU, DV,

DW

M6

3.0 5.5

(10)

R5.5-6

M8

9.0 to 11.0

100 (4/0)

100-8

Converter

P, N

M10

12 to 20

Bus bar

attached to the

converter

L1, L2, L3

M10

12 to 20

100 (4/0)

R100-10

1, 2

M10

12 to 20

100 (4/0)

R100-10

CN101

(L1C, L2C)

(Connector)

1.25 (16)

B1, B2

M10

12 to 20

14 (6)

R14-10

M8

9.0 to 11.0

100 (4/0)

100-8

(cont’d)

Combination of

SERVOPACK and

Converter

*1

Terminal

Symbols

Screw Size

for

Terminals

Tightening

Torque

(Nxm)

HIV Wire Size

in mm

2

(AWG)

Crimp Terminal

Model

(Made by J.S.T.

Mfg Co., Ltd.)

*2

Advertising