Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 71

3.4 Main Circuit Wiring
3-23
Wiring and Connection
∗1. Use SERVOPACKs and converters in the specified combinations.
∗2. Use the crimp terminals that are recommended by Yaskawa or an equivalent.
SGDV-161H
SGDV-
COA3GAA
SERVO-
PACK
P, N
M8
15.0
Bus bar
attached to the
converter
–
U, V, W
M8
3.0
100 (4/0)
CB100-S8
DU, DV,
DW
M6
3.0 5.5
(10)
R5.5-6
M8
9.0 to 11.0
100 (4/0)
100-8
Converter
P, N
M10
12 to 20
Bus bar
attached to the
converter
–
L1, L2, L3
M10
12 to 20
60 (2/0)
R60-10
1, 2
M10
12 to 20
60 (2/0)
R60-10
CN101
(L1C, L2C)
–
(Connector)
–
1.25 (16)
–
B1, B2
M10
12 to 20
14 (6)
R14-10
M8
9.0 to 11.0
60 (2/0)
R60-8
SGDV-201H
SGDV-
COA3GAA
SERVO-
PACK
P, N
M10
12 to 20
Bus bar
attached to the
converter
–
U, V, W
M10
30.0
100 (4/0)
R100-10
DU, DV,
DW
M6
3.0 5.5
(10)
R5.5-6
M8
9.0 to 11.0
100 (4/0)
100-8
Converter
P, N
M10
12 to 20
Bus bar
attached to the
converter
–
L1, L2, L3
M10
12 to 20
100 (4/0)
R100-10
1, 2
M10
12 to 20
100 (4/0)
R100-10
CN101
(L1C, L2C)
–
(Connector)
–
1.25 (16)
–
B1, B2
M10
12 to 20
14 (6)
R14-10
M8
9.0 to 11.0
100 (4/0)
100-8
(cont’d)
Combination of
SERVOPACK and
Converter
*1
Terminal
Symbols
Screw Size
for
Terminals
Tightening
Torque
(Nxm)
HIV Wire Size
in mm
2
(AWG)
Crimp Terminal
Model
(Made by J.S.T.
Mfg Co., Ltd.)
*2