1) single-axis application three-phase 200 v, 4 main circuit wiring 3-35 – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 83

3.4 Main Circuit Wiring
3-35
Wiring and Connection
The following diagrams show wiring examples of the SERVOPACK and converter.
(1) Single-axis Application
Three-phase 200 V
1
2
1FLT
3SA
M
ENC
+24 V
0 V
ALM+
ALM-
CN1
31
32
1D
1Ry
1Ry
1Ry
U
C B
A
V
W
DB24
DBON
P
P
B1
B2
L1
1
L2
L3
L1C
L2C
U
V
W
R S
T
1QF
2KM
1KM
1KM
2KM
1SA
2SA
1KM
1KM
a
b
1b
a
b
CN901
CN901
CN103
CN103
CN101
CN2
DU
DV
DW
CN115
N
N
2QF
Three-phase,
200 VAC
Regenerative
resistor unit
Servo power
supply ON
Servo power
supply OFF
Converter
SERVOPACK
Dynamic
brake unit
Fan
Thermostat
1QF: Molded-case circuit breaker
2QF: Molded-case circuit breaker
1FIL: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode