3.4 Main Circuit Wiring
3-37
Wiring and Connection
(2) Multi-axis Application
Connect the alarm output (ALM) terminals for the three SERVOPACKs in series to
enable alarm detection relay 1RY to operate.
When the alarm occurs, the ALM output signal transistor is turned OFF.
The following diagram shows a wiring example for three-phase, 400-VAC SERVO-
PACK with converter.
M
24 V
0 V
CN101
CN103
CN103
CN901
CN901
CN103
CN103
CN901
CN901
CN103
CN103
CN901
CN901
24 V
0 V
CN101
24 V
0 V
CN101
1FLT
3SA
M
+24 V
ALM+
ALM-
CN1
31
32
1D
1Ry
1Ry
1Ry
U
V
W
P
P
N
N
L1
1
1b
1
1b
1
1b
L2
L3
U
V
W
R
S T
1QF
2KM
1KM
1KM
2KM
1SA
2SA
1KM
1KM
a
C B A
C B A
C B A
b
a
b
1PL
ALM+
ALM-
CN1
31
32
U
V
W
P
P
N
N
L1
L2
L3
M
U
V
W
U
V
W
P
P
N
N
L1
L2
L3
0 V
ALM+
ALM-
CN1
31
32
U
V
W
+
-
2QF
3QF
4QF
Fan
Fan
Fan
Thermostat
(For servo alarm
display)
supply ON
Servo power
supply OFF
Servo power
Three-phase,
400 VAC
Relay
terminal
Relay
terminal
Relay
terminal
Relay
terminal
Relay
terminal
Relay
terminal
DC power
supply (24 V)
Converter
100/200 VAC
SERVOPACK
Converter SERVOPACK
Converter SERVOPACK
Thermostat
Thermostat
1QF: Molded-case circuit breaker
2QF: Molded-case circuit breaker
3QF: Molded-case circuit breaker
4QF: Molded-case circuit breaker
1FIL: Noise filter
1KM: Magnetic contactor
(for control power supply)
2KM: Magnetic contactor
(for main power supply)
1Ry: Relay
1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode