Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 36

2 Installation
2.4.1 SGDV-01A (Analog Pulse Model)
2-14
∗1. Surge absorber model: LT-C32G801WS (manufactured by Soshin Electric Co., Ltd.)
∗2. The noise filter differs in accordance with the converter used.
∗3. Surge absorber model: LT-C12G801WS (manufactured by Soshin Electric Co., Ltd.)
∗4. Noise filter model: HF2005A-UP (manufactured by Soshin Electric Co., Ltd.)
Symbol
Cable Name
Specification
c
Main circuit cable
Shield cable
d
I/O signal cable
Shield cable
e
Safety signal cable
Shield cable
f
Dynamic brake unit signal cable
Non-shield cable
g
Dynamic brake unit power cable
Non-shield cable
h
Motor fan cable
Shield cable
i
Regenerative resistor unit cable
Non-shield cable
j
I/O signal connection cable
Shield cable
k
24 VDC control power cable
Non-shield cable
l
Motor main circuit cable
Shield cable
Encoder cable
Shield cable
Combination of SERVOPACK and
Converter
Noise Filter
Model
Manufacturer
SERVOPACK
Model:
SGDV-
Converter
Model:
SGDV-COA
121H
2BAA
HF3150C-UQB
Soshin Electric
Co., Ltd.
161H
3GAA
HF3200C-UQB
201H
3GAA
HF3250C-UQB