3 interconnecting terminals, 1) sgdv-coa2baa or -coa3zda converter – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual

Page 67

Advertising
background image

3.4 Main Circuit Wiring

3-19

Wiring and Connection

3.4.3 Interconnecting Terminals

Use the bus bars that are provided with the converter to connect the P and N terminals
between the SERVOPACK and the converter.

The bus bars are different for different converter models.

(1) SGDV-COA2BAA or -COA3ZDA Converter

Attach the bus bars as shown in the following figure.

Note: The shapes of the ends of the bus bars are different for the SERVOPACK and converter

connections and for the P terminal and N terminal connections.

Converter’s P terminal

Converter’s N terminal

SERVOPACK’s P terminal

SERVOPACK’s N terminal