3.4 Main Circuit Wiring
3-17
Wiring and Connection
CN101
CN103, CN104
SGDV-COA3GAA or -COA5EDA Converter
P, N
L1, L2, L3
B1, B2
1,
ޓ2
Terminals
Name
Specifications
L1, L2, L3
Main circuit power input
terminals
SGDV-COAAA: Three-phase, 200 to 230 VAC,
+10% to -15%, 50/60 Hz
SGDV-COADA: Three-phase, 380 to 480 VAC,
+10% to -15%, 50/60 Hz
CN101
Control power input
connector
SGDV-COAAA: Single-phase, 200 to 230 VAC,
+10% to -15%, 50/60 Hz
SGDV-COADA: 24 VDC,
±15%
Mating connector model: 231-202/026-000 (Manufac-
tured by Wago Company of Japan, Ltd.)
P, N
Main circuit DC voltage
output terminals
Connect these terminals to the P and N terminals on the
SERVOPACK.
Ground terminal
Connect this terminal to the power supply ground termi-
nal and then ground it.
B1, B2
Regenerative resistor
connection terminals
Connect these terminals to the regenerative resistor unit.
1, 2
DC reactor connection
terminals
Remove the short bar before you connect a DC reactor.
Pin 2: 24 V
Pin 1: 0 V