2.4 EMC Installation Conditions

2-15

Installation

„

Three-phase 400 V

• SERVOPACK: SGDV-†††J01A (††† = 750, 101, 131)
• Converter: SGDV-COA††DA (†† = 3Z, 5E)

Note: 1T: 1 turn

2T: 2 turns
For details, refer to 2.4.5 Other Precautions.



Shield box

1T

Converter

L1, L2, L3

CN101
24 V, 0 V

CN103, CN104

SERVOPACK

U, V, W

Fan

Servomotor

Encoder

P

N

P

N

Regenerative

resistor

CN103, CN104

*2

*3

*4

*5

B1, B2

CN901

CN901

CN8

CN1

CN115

DU, DV, DW

1T

1T

1T

2T

CN2

Clamp

Clamp

Clamp

*1

1T

Core

1T

Core

1T

Core

Core

Core

Core

Core

Core

Core

Core

1T

1T

1T

1T

Dynamic

brake unit

Power supply:
Three-phase
400 VAC

Power supply:
Single-phase
200 VAC

Surge

absorber

Surge

absorber

Core

Core

Clamp

Clamp

Clamp

Noise

filter

Noise

filter

Control

power

supply

24 VDC

Host

controller

Safety
device