2.4 EMC Installation Conditions
2-15
Installation
Three-phase 400 V
• SERVOPACK: SGDV-J01A ( = 750, 101, 131)
• Converter: SGDV-COADA ( = 3Z, 5E)
Note: 1T: 1 turn
2T: 2 turns
For details, refer to 2.4.5 Other Precautions.
Shield box
1T
Converter
L1, L2, L3
CN101
24 V, 0 V
CN103, CN104
SERVOPACK
U, V, W
Fan
Servomotor
Encoder
P
N
P
N
Regenerative
resistor
CN103, CN104
*2
*3
*4
*5
B1, B2
CN901
CN901
CN8
CN1
CN115
DU, DV, DW
1T
1T
1T
2T
CN2
Clamp
Clamp
Clamp
*1
1T
Core
1T
Core
1T
Core
Core
Core
Core
Core
Core
Core
Core
1T
1T
1T
1T
Dynamic
brake unit
Power supply:
Three-phase
400 VAC
Power supply:
Single-phase
200 VAC
Surge
absorber
Surge
absorber
Core
Core
Clamp
Clamp
Clamp
Noise
filter
Noise
filter
Control
power
supply
24 VDC
Host
controller
Safety
device