background image

2 Installation

2.4.2 SGDV-††††11A (M-II Model)

2-20

∗1. Surge absorber model: LT-C35G102WS (manufactured by Soshin Electric Co., Ltd.)

∗2. The noise filter differs in accordance with the converter used.

∗3. Surge absorber for 200 V: LT-C12G801WS (manufactured by Soshin Electric Co., Ltd.)

∗4. Noise filter for 200 V: HF2005A-UP (manufactured by Soshin Electric Co., Ltd.)

∗5. 24-VDC control power supply: Power supply with double insulation or reinforced insula-

tion that complies with the CE Marking.

Symbol

Cable Name

Specification

c

Main circuit cable

Shield cable

d

Control power cable

Shield cable

e

MECHATROLINK-II communica-

tion cable

Shield cable

f

I/O signal cable

Shield cable

g

Safety signal cable

Shield cable

h

Dynamic brake unit signal cable

Non-shield cable

i

Dynamic brake unit power cable

Non-shield cable

j

Motor fan cable

Shield cable

k

Regenerative resistor unit cable

Non-shield cable

l

I/O signal connection cable

Shield cable

24 VDC control power cable

Non-shield cable

Motor main circuit cable

Shield cable

Encoder cable

Shield cable

Combination of SERVOPACK and

Converter

Noise Filter

Model

Manufacturer

SERVOPACK

Model:

SGDV-

Converter

Model:

SGDV-COA

750J

3ZDA

HF3150C-UQB

Soshin Electric

Co., Ltd.

101J

5EDA

HF3150C-UQB

131J

5EDA

HF3200C-UQB