Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 42

2 Installation
2.4.2 SGDV-11A (M-II Model)
2-20
∗1. Surge absorber model: LT-C35G102WS (manufactured by Soshin Electric Co., Ltd.)
∗2. The noise filter differs in accordance with the converter used.
∗3. Surge absorber for 200 V: LT-C12G801WS (manufactured by Soshin Electric Co., Ltd.)
∗4. Noise filter for 200 V: HF2005A-UP (manufactured by Soshin Electric Co., Ltd.)
∗5. 24-VDC control power supply: Power supply with double insulation or reinforced insula-
tion that complies with the CE Marking.
Symbol
Cable Name
Specification
c
Main circuit cable
Shield cable
d
Control power cable
Shield cable
e
MECHATROLINK-II communica-
tion cable
Shield cable
f
I/O signal cable
Shield cable
g
Safety signal cable
Shield cable
h
Dynamic brake unit signal cable
Non-shield cable
i
Dynamic brake unit power cable
Non-shield cable
j
Motor fan cable
Shield cable
k
Regenerative resistor unit cable
Non-shield cable
l
I/O signal connection cable
Shield cable
24 VDC control power cable
Non-shield cable
Motor main circuit cable
Shield cable
Encoder cable
Shield cable
Combination of SERVOPACK and
Converter
Noise Filter
Model
Manufacturer
SERVOPACK
Model:
SGDV-
Converter
Model:
SGDV-COA
750J
3ZDA
HF3150C-UQB
Soshin Electric
Co., Ltd.
101J
5EDA
HF3150C-UQB
131J
5EDA
HF3200C-UQB