3.4 Main Circuit Wiring

3-29

Wiring and Connection

„

For Three-phase, 400V

Combination of

SERVOPACK and

Converter

*

Terminal

Symbols

Screw Size

for

Terminals

Tightening

Torque

(Nxm)

Wire Size

AWG

SGDV-750J

SGDV-

COA3ZDA

SERVOPACK

P, N

M8

15.0

Bus bar

attached to

the converter

U, V, W

M8

3.0

3

DU, DV, DW

M6

3.0

10

M8

9.0 to 11.0

3

Converter

P, N

M8

3.0

Bus bar

attached to

the converter

L1, L2, L3

M8

3.0

3

1, 2

M8

3.0 3

CN101

(24 V, 0 V)

(Connector)

14

B1, B2

M8

3.0

8

M8

9.0 to 11.0

3

SGDV-101J

SGDV-

COA5EDA

SERVOPACK

P, N

M8

15.0

Bus bar

attached to

the converter

U, V, W

M8

3.0

1

DU, DV, DW

M6

3.0

10

M8

9.0 to 11.0

1

Converter

P, N

M10

12 to 20

Bus bar

attached to

the converter

L1, L2, L3

M10

12 to 20

2

1, 2

M10

12 to 20

2

CN101

(24 V, 0 V)

(Connector)

14

B1, B2

M10

12 to 20

8

M8

9.0 to 11.0

2