6 selecting and connecting a dynamic brake unit, 1 selection, 2 connections – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 89: 1) using a dynamic brake unit from yaskawa

3.6 Selecting and Connecting a Dynamic Brake Unit
3-41
Wiring and Connection
3.6
Selecting and Connecting a Dynamic Brake Unit
To use the dynamic brake (DB), externally connect a dynamic brake unit or dynamic
brake resistor to the SERVOPACK to process the dynamic braking energy.
Set Pn001 to n.2 if you do not use the dynamic brake. In this case, it is not nec-
essary to connect a dynamic brake unit.
3.6.1 Selection
Use the following tables to select a dynamic brake unit or dynamic brake resistor.
3.6.2 Connections
(1) Using a Dynamic Brake Unit from Yaskawa
When connecting a dynamic brake, refer to the following diagram.
Note: The dynamic brake answer function cannot be used, because the contactor has no auxil-
iary contacts.
SERVOPACK
Model:
SGDV-
Dynamic Brake
Unit Model
Resistance
Specifications
(Star Wiring
)
Dynamic Brake Contactor and
Surge Absorption Unit
121H, 161H,
201H
JUSP-DB02-E
180 W, 0.3
Ω
Built into dynamic brake unit.
750J, 101J
JUSP-DB04-E
180 W, 0.8
Ω
131J
JUSP-DB06-E
300 W, 0.8
Ω
DU
DV
DW
SERVOPACK
DU
DV
DBON
24 V
DB
DW
DB24
DBON
DB24
Dynamic brake unit
CN115
0 V
DB