2 connecting the connectors – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual
Page 66

3 Wiring and Connection
3.4.2 Connecting the Connectors
3-18
3.4.2 Connecting the Connectors
Connect CN901 and CN103 on the SERVOPACK and converter as shown in the fol-
lowing figure.
CN103,
CN104
Control power output
connectors
CN103 and CN104 output 24 VDC to the SERVO-
PACK.
For a 400-V system, the 24-VDC (
±15%) input is output
unaltered from CN103. CN104 provides the same out-
put, but it is normally not necessary to connect it.
(cont’d)
Terminals
Name
Specifications
CN901: I/O signal connector between the
SERVOPACK and converter
CN103: Control power supply input connector
I/O signal connection cable
24-VDC control power supply cable
SERVOPACK
Converter
Cable Name
Cable Model
Cable
Length
Description
IO signal connection
cable
JZSP-CVI02-A4-E
0.4 m
This cable connects the CN901
connectors on the SERVOPACK
and converter.
24-VDC control
power supply cable
JZSP-CVG00-A4-E 0.4 m
This cable connects the
CN103(CN104) connectors on the
SERVOPACK and converter.