2 connecting the connectors – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual

Page 66

Advertising
background image

3 Wiring and Connection

3.4.2 Connecting the Connectors

3-18

3.4.2 Connecting the Connectors

Connect CN901 and CN103 on the SERVOPACK and converter as shown in the fol-
lowing figure.

CN103,

CN104

Control power output

connectors

CN103 and CN104 output 24 VDC to the SERVO-

PACK.

For a 400-V system, the 24-VDC (

±15%) input is output

unaltered from CN103. CN104 provides the same out-

put, but it is normally not necessary to connect it.

(cont’d)

Terminals

Name

Specifications

CN901: I/O signal connector between the
SERVOPACK and converter

CN103: Control power supply input connector

I/O signal connection cable

24-VDC control power supply cable

SERVOPACK

Converter

Cable Name

Cable Model

Cable

Length

Description

IO signal connection

cable

JZSP-CVI02-A4-E

0.4 m

This cable connects the CN901

connectors on the SERVOPACK

and converter.

24-VDC control

power supply cable

JZSP-CVG00-A4-E 0.4 m

This cable connects the

CN103(CN104) connectors on the

SERVOPACK and converter.

Advertising