background image

2 Installation

2.4.5 Other Precautions

2-26

„

Fixing the Cable

Fix and ground the cable shield using a piece of conductive metal.

• Example of Cable Clamp

„

Shield Box

A shield box, which is a closed metallic enclosure, is effective as reinforced shielding
against electromagnetic interference (EMI) from SERVOPACKs and converters. The
structure of the box should allow the main body, door, and cooling unit to be attached
to the ground. The box opening should be as small as possible.

Note: Do not connect the digital operator and the analog monitor cable to the SERVOPACK

and the converter during operations. Connect them only when the machinery is stopped
during maintenance.

Host controller side

Ground plate

Cable

Cable
clamp

Shield (cable sheath stripped)

Fix and ground the cable shield
using a piece of conductive metal.

Remove paint on mounting surface.