Three-phase 400 v, Installation, 4 emc installation conditions 2-19 – Yaskawa Sigma-5 Series User Manual:: For Use with Large-Capacity Models-Setup. Rotary Motors User Manual

Page 41

Advertising
background image

2.4 EMC Installation Conditions

2-19

Installation

„

Three-phase 400 V

• SERVOPACK: SGDV-†††J11A (††† = 750, 101, 131)
• Converter: SGDV-COA††DA (†† = 3Z, 5E)

Note: 1T: 1 turn

2T: 2 turns
For details, refer to 2.4.5 Other Precautions.



Shield box

1T

Converter

L1, L2, L3

CN101
24 V, 0 V

CN103, CN104

SERVOPACK

U, V, W

Fan

Servomotor

Encoder

P

N

P

N

Regenerative

resistor

CN103, CN104

*2

*3

*4

*5

B1, B2

CN901

CN901

CN8

CN1

CN6A, CN6B

CN115

DU, DV, DW

1T

1T

1T

2T

2T

CN2

Clamp

Clamp

Clamp

Clamp

Clamp

Clamp

Clamp

Surge

absorber

Surge

absorber

*1

Noise

filter

Noise

filter

Control

power

supply

24 VDC

1T

Core

Core

Core

Core

Core

Core

Core

Core

Core

1T

1T

I/O control

device

Safety
device

Dynamic

brake unit

MECHATROLINK-

II

controller

Power supply:
Three-phase
400 VAC

Power supply:
Single-phase
200 VAC

Core

Core

Core

Core

1T

1T

1T

1T

Advertising