Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Analog Voltage and Pulse Train Reference User Manual

Page 136

Advertising
background image

5.2 Basic Functions Settings

5-15

5

Ope

rat

ion

Stopping Method for Servomotor for Gr.1 Alarms

The stopping method of the servomotor when a Gr.1 alarm occurs is the same as that in (1) Stopping Method
for Servomotor after /S-ON Signal is Turned OFF
.

∗ Always connect a dynamic brake circuit for these settings.

Stopping Method for Servomotor for Gr.2 Alarms

∗1. Always connect a dynamic brake circuit for these settings.

∗2. Zero-speed stopping: The speed reference is set to 0 to stop quickly.

Note: The setting of Pn00B.1 is effective for position control and speed control. Pn00B.1 will be ignored for torque control

and only the setting of Pn001.0 will be valid.

Parameter

Stop Mode

Mode After

Stopping

When Enabled

Classification

Pn001

n.

0

*

[Factory setting] DB

DB

After restart

Setup

n.

1

*

Coast

n.

2

Coast

Coast

Parameter

Stop Mode

Mode After

Stopping

When Enabled

Classification

Pn00B

Pn001

n.

0

[Factory setting]

n.

0

*1

[Factory setting] Zero-speed

stopping

*2

DB

After restart

Setup

n.

1

*1

Coast

n.

2

n.

1

n.

0

*1

[Factory setting] DB

DB

n.

1

*1

Coast

n.

2

Coast