4 setting the dynamic brake answer function – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Analog Voltage and Pulse Train Reference User Manual

Page 98

Advertising
background image

3 Wiring and Connection

3.8.4 Setting the Dynamic Brake Answer Function

3-50

3.8.4 Setting the Dynamic Brake Answer Function

With the dynamic brake answer function, you can use auxiliary contacts of the contactor that is used in the

dynamic brake circuit and the dynamic brake answer signal (/DBANS) to detect welding or failure to opera-

tion.
To use the dynamic brake answer function, select a contactor that has auxiliary contacts.

Note: The dynamic brake answer function cannot be used with a Yaskawa dynamic brake unit because there are no auxil-

iary contacts on the contactor.

The dynamic brake answer signal is assigned with Pn515.2.

Example
If you use a dynamic brake contactor with NO contacts, input the dynamic brake answer signal (a signal from

NO auxiliary contacts) to CN1-45 and set Pn515 to n. E

.

Parameter

Meaning

When

Enabled

Classification

Pn515

n. 0

Detects dynamic brake (DB) contactor errors when the

input signal of CN1-40 is ON (closed) while the DB is
applied.

After restart

Setup

n. 1

Detects DB contactor errors when the input signal of
CN1-41 is ON (closed) while the DB is applied.

n. 2

Detects DB contactor errors when the input signal of
CN1-42 is ON (closed) while the DB is applied.

n. 3

Detects DB contactor errors when the input signal of
CN1-43 is ON (closed) while the DB is applied.

n. 4

Detects DB contactor errors when the input signal of
CN1-44 is ON (closed) while the DB is applied.

n. 5

Detects DB contactor errors when the input signal of
CN1-45 is ON (closed) while the DB is applied.

n. 6

Detects DB contactor errors when the input signal of
CN1-46 is ON (closed) while the DB is applied.

n. 7

Disables DB contactor error detection of DB answer
signal 1.

n. 8
[Factory

setting]

n. 9

Detects DB contactor errors when the input signal of
CN1-40 is OFF (open) while the DB is applied.

n. A

Detects DB contactor errors when the input signal of
CN1-41 is OFF (open) while the DB is applied.

n. B

Detects DB contactor errors when the input signal of
CN1-42 is OFF (open) while the DB is applied.

n. C

Detects DB contactor errors when the input signal of
CN1-43 is OFF (open) while the DB is applied.

n. D

Detects DB contactor errors when the input signal of

CN1-44 is OFF (open) while the DB is applied.

n. E

Detects DB contactor errors when the input signal of
CN1-45 is OFF (open) while the DB is applied.

n. F

Detects DB contactor errors when the input signal of
CN1-46 is OFF (open) while the DB is applied.

Advertising