2 connecting the converter to the servopack, 1 connecting the connectors, 2 interconnecting terminals – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Analog Voltage and Pulse Train Reference User Manual

Page 69: 1) sgdv-coa2baa, -coa3zda converters, Analog

Advertising
background image

3.2 Connecting the Converter to the SERVOPACK

3-21

3

Wi

ring an

d Conn

ecti

on

3.2 Connecting the Converter to the SERVOPACK

3.2.1 Connecting the Connectors

Connect CN901 and CN103 on the SERVOPACK and converter as shown in the following figure.

3.2.2 Interconnecting Terminals

Use the busbars that are provided with the converter to connect the P and N terminals between the SERVO-

PACK and the converter.

The busbars are different for different converter models.

(1) SGDV-COA2BAA, -COA3ZDA Converters

Attach the busbars as shown in the following figure.

Note: The shapes of the ends of the busbars are different for the SERVOPACK and converter connections and for the P ter-

minal and N terminal connections.

SERVOPACK

Converter

CN901: I/O signal connector between the SERVOPACK and converter

CN103: Control power supply input connector

I/O signal connection cable

24-VDC control power supply cable

Analog

Cable Name

Cable Model

Cable Length

Description

IO signal connection cable JZSP-CVI02-A4-E

0.4 m

This cable connects the CN901 connectors on
the SERVOPACK and converter.

24-VDC control power
supply cable

JZSP-CVG00-A4-E

0.4 m

This cable connects the CN103(CN104) con-
nectors on the SERVOPACK and converter.

Advertising