5 zero clamp function, Analog – Yaskawa Sigma-5 Large Capacity Users Manual: Design and Maintenance-Rotary Motors-Analog Voltage and Pulse Train Reference User Manual

Page 148

Advertising
background image

5.3 Speed Control

5-27

5

Ope

rat

ion

5.3.5 Zero Clamp Function

The zero clamp function locks the servo when the input voltage of the speed reference (V-REF) drops below

the speed set in the zero clamp level (Pn501) while the zero clamp signal (/P-CON or /ZCLAMP) is ON. The

SERVOPACK internally forms a position loop, ignoring the speed reference.

The zero clamp function is used for systems in which the host controller does not form a position loop for the

speed reference input.

The servomotor is clamped within one pulse of the position when the zero clamp function is turned ON, and

will still return to the zero clamp position even if it is forcibly rotated by external force.

Adjust the position loop gain (Pn102) if the servomotor oscillates in the zero clamp state. If the gain switching

function is used, adjusting the 2nd position loop gain (Pn106) is required as well. For details, refer to 6.8.1
Switching Gain Settings
.

(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)

When Pn000.1 is set to A, the control method becomes "speed control <=> speed control with zero clamp

function" and the /P-CON signal is used as a zero clamp signal.

Host controller

Speed reference

Stops precisely!

V-REF

/P-CON

Zero clamp

(/ZCLAMP)

Analog

V-REF speed reference

Speed

/P-CON (/ZCLAMP)
input signal

Zero clamp
function

Time

ON

ON

ON

OFF

OFF

OFF

Set value for zero

clamp level (Pn501)

Analog

Type

Connector

Pin Number

Setting

Meaning

Input

/P-CON

CN1-41
[Factory setting]

ON
(closed)

The zero clamp function will be turned ON if the input volt-
age of the speed reference (V-REF) drops below the set speed
in the zero clamp level (Pn501).

OFF
(open)

Turns OFF the zero clamp function.

Parameter

Control Method

When Enabled Classification

Pn000

n.

A

Speed control <=>
speed control with zero clamp function

After restart