3 Wiring and Connection

3.1.1 Main Circuit Terminals

3-4

Converter

CN101

CN103,
CN104

L1, L2, L3

B1, B2

P, N

1,

ޓ2

CN101

CN103,
CN104

P, N

L1, L2, L3

B1, B2

1,

ޓ2

Converter

SGDV-COA2BAA
SGDV-COA3ZDA

Converter

SGDV-COA3GAA
SGDV-COA5EDA

Terminals

Name

Specifications

L1, L2, L3

Main circuit power input terminals

SGDV-COA

AA: Three-phase, 200 to 230 VAC, +10% to -

15%, 50/60 Hz
SGDV-COA

DA: Three-phase, 380 to 480 VAC, +10% to -

15%, 50/60 Hz

CN101

Control power input connector

SGDV-COA

AA: Single-phase, 200 to 230 VAC, +10% to -

15%, 50/60 Hz
SGDV-COA

DA: 24 VDC,

±15%

Mating connector model: 231-202/026-000 (Manufactured by

Wago Company of Japan, Ltd)

P, N

Main circuit DC voltage output ter-

minals

Connect these terminals to the P and N terminals on the SERVO-
PACK.

Ground terminal

Connect this terminal to the power supply ground terminal and
then ground it.

B1, B2

Regenerative resistor connection

terminals

Connect these terminals to the regenerative resistor unit.

1, 2

DC reactor connection terminals

Remove the short bar before you connect a DC reactor.

CN103,

CN104

Control power output connectors

CN103 and CN104 output 24 VDC to the SERVOPACK.
For a 400-V system, the 24-VDC (

±15%) input is output unaltered

from CN103. CN104 provides the same output, but it is normally
not necessary to connect it.

Pin 2: 24 V

Pin 1: 0 V